  1. Goodman Gas Furnace Control Board Keeps Failing - HVAC-Talk

    Mar 17, 2016 · The Goodman control boards were pretty reliable in my experience - so consistent repeated board failures sounds like water-exposure to me. Possibly a problem with the power supply …

  2. Goodman control board not triggering inducer relay - HVAC-Talk

    Nov 3, 2013 · I removed the relay to troubleshoot, relay clicks fine when connected to various exteranl power sources (6V-24V). With the relay removed, I get the expected voltage across the control …

  3. Goodman Fan Controller board issues - HVAC-Talk

    May 9, 2022 · Good evening gents. This “shouldn’t” fall into diy, but in case it does, I apologize. The fan controller board on my 3 year old Goodman keeps failing every summer. It’s been replaced 3 times …

  4. Goodman/Amana fault code 8.8 - HVAC-Talk

    Feb 5, 2021 · Obviously there's fault code 8.8 in the manufacturer's literature so I called Goodman tech support, just said to replace the board. I also called a tech support guy from Universal Supply group, …

  5. New Control Board but Compressor not turning on now. Need help.

    Sep 22, 2022 · Need help. My Goodman AC stopped working so from previous experience I thought it may be a new control board so I ordered one off of Ebay. The model for the part was PCBKF102. …

  6. Goodman ECM blower motor not working - HVAC-Talk

    Aug 17, 2024 · We have a Goodman GSZC180601 2 stage, 5 ton system with a Goodman AVPTC61D14AC air handler. The air handler blower motor is a Goodman 0131M01011 ECM 1 ton …

  7. Goodman ECM trouble - HVAC-Talk

    Jan 5, 2006 · I am troubleshooting a GE ECM motor in a goodman air handler.. The motor only rocks the fan a few seconds and never takes off.. I jumpered the required pins on the motor module to get it to …

  8. Goodman 2.5 ton hp w/10k heat blowing low voltage 5 amp fuse

    Mar 25, 2018 · Is the back of the control board shorting against the chassis? Is there a safety wired off of R that has a rubbed-through wire on a pipe? Most likely this is only possible if the transformer …

  9. New Goodman furnace not working in heating mode - HVAC-Talk

    Mar 4, 2025 · I installed new Goodman furnace model# GR9S960803BNAA and is not working in heating mode. It’s getting code EE1 , but I checked all 5 switches and all are good , it’s no shortage …

  10. Goodman Model# GMES801005CNAA Control Board Failure - HVAC-Talk

    Sep 16, 2022 · Goodman Model# GMES801005CNAA Control Board Failure Jump to Latest 1.8K views 2 replies 3 participants last post by tinman74 19h ago C